BSBDN - VACTRA OIL NUMBER 2, IMTC0810
- MSDS: BSBDN
- Manufacturer: MOBIL OIL CORP
- Product Name: VACTRA OIL NUMBER 2, IMTC0810
- National Stock Number: 1220-LLF009102
Product Identification
Product ID:VACTRA OIL NUMBER 2, IMTC0810
MSDS Date:12/30/1992
FSC:1220
NIIN:LLF009102
MSDS Number: BSBDN
Responsible Party
FAIRFAX, VA 22037
US
Emergency Phone: 800-227-0707
Info Phone: 800-227-0707
Cage: 51545
Contractor
Telephone: 800--662-4525
Cage: 51545
Ingredients
ADDITIVES (MAY CONTAIN ONE OR MORE OF INGS 8-10)
OSHA PEL N/K
ACGIH TLV: N/K
ALKENES, C15-20 A-, POLYMERS WITH COTTONSEED OIL AND SULFUR
CAS: 68603-33-8
Fraction By Weight: <3%
OSHA PEL N/K
ACGIH TLV: N/K
ANIMAL FATTY OIL; (OILS, LARD)
CAS: 8016-28-2
Fraction By Weight: 1%
OSHA PEL N/K
ACGIH TLV: N/K
TOLUENE; (BENZENE, METHYL-) (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 0.002%
OSHA PEL 100 PPM; 150 STEL
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
9-OCTADECENYLAMINE, (Z)-; (OLEYL AMINE)
CAS: 112-90-3
RTECS: RG4130000
OSHA PEL N/K
ACGIH TLV: N/K
< 4.00 (WT %); 0.295 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
CHARACTERISTICS AT TIME OF DISPOSAL.
RTECS: 9999999ZZ
FACILITY. USE OF THESE METH IS SUBJECT TO
RTECS: 9999999ZZ
REGULATIONS & CONSIDERATION OF PRODUCT
RTECS: 9999999ZZ
5 MG/M3
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
OILS; (BASE OILS) (CONTAINS ONE OR MORE OF INGS 2-9)
Fraction By Weight: >95%
OSHA PEL N/K
ACGIH TLV: N/K
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-DEWAXED HEAVY
CAS: 64742-65-0
RTECS: PY8038501
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: SEE INGREDIENT
(DISTILLATES (PETROLEUM), SOLVENT-DEWAXED HEAVY
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)
CAS: 64742-54-7
RTECS: PY8035501
OSHA PEL 5 MG/M3 (OIL, MIST)
ACGIH TLV: SEE INGREDIENT
5 MG/M3
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
5
CAS: 64742-01-4
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: SEE INGREDIENT
SOLVENT, DEWAXED RESIDUAL OIL (PETRO); (RESIDUAL OILS
CAS: 64742-62-7
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: SEE INGREDIENT
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED
CAS: 64741-88-4
RTECS: PY8040501
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: SEE INGREDIENT
Hazards
LD50 LC50 Mixture:LD50 (ORAL, RAT): NONTOXIC
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SLIGHT SKIN IRRITATION. SEVERELY
SOLVENT REFINED & SEVERELY HYDROTREATED MINERAL BASE OILS HAVE BEEN
TESTED BY DERMAL APPLICATION TO RATS 5 DAYS/WK FOR 90 DAYS AT DOSES
HIGHER THAN EXPECTED DURING NOR MAL INDUSTRIAL EXPOSURE. EXTENSIVE
EVALUATIONS INCLUDING MICROSCOPIC EXAM OF INTERNAL ORGANS & (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CLINICAL CHEMISTY OF BODY FLUIDS,
SHOWED NO ADVERSE EFFECTS. THE BASE OILS IN PRODUCT ARE SEVERELY
SOLVENT REFINED &/OR SEVERELY HYDROTREATED. CHRONIC MOUSE SKIN
PAINTING STUDIES OF SIMILAR O ILS SHOWED NO EVIDENCE OF
CARCINOGENIC EFFECTS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES. IF
IRRITATION PERSISTS, CALL MD. SKIN:WASH CONTACT AREAS WITH SOAP &
WATER. INHAL:REMOVE FROM FURTHER EXPOSURE. IF RESPIRATORY
IRRITATION, DIZ ZINESS, NAUSEA OR UNCONSCIOUSNESS OCCURS, SEEK
IMMEDIATE MEDICAL ASSISTANCE & CALL MD. IF BREATHING HAS STOPPED,
USE MOUTH TO MOUTH RESUSCITATION. INGEST:IF UNCOMFORTABLE SEEK
MEDICAL ASSISTANCE.
Fire Fighting
Flash Point Method:COC
Flash Point:>350F,>177C
Lower Limits:0.6%
Upper Limits:7%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER/FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE EXPOS CNTNRS
COOL. WATER SPRAY MAY BE USED TO (SUPDAT)
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:RPT SPILLS AS REQD TO APPROP AUTH. US COAST
GUARD REGS REQ IMMED REPORTING OF SPILLS THAT COULD REACH WATERWAYS
INCL INTERMITTENT DRY CREEKS. RPT SPILL TO COAST GUARD @
800-424-8802. IN CASE OF ACCIDE NT/ROAD SPILL NOTIFY CHEMTREC @
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NO SPECIAL PRECAUTIONS REQUIRED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NO SPECIAL REQUIREMENTS UNDER ORDINARY
CONDITIONS OF USE AND WITH ADEQUATE VENTILATION.
Ventilation:USE IN WELL VENTILATED AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC:FLUSH SPILLS AWAY FROM EXPOS. PVNT RUNOFF FROM FIRE
CONTROL/DILUTION FROM ENTERING STREAMS, SEWERS/DRINKING WATER
SUPPLY. SPILL PROC:800-424-9300. ABSORB ON FIRE RETARDANT TREATED
SAWD UST, DIATOMACEOUS EARTH, ETC. SHOVEL UP& DISP OF @ APPROP
WASTE DISP FACILITY I/A/W/CURRENT LAWS & REGS & PROD (ING 16)
Chemical Properties
HCC:V1
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<0.1 @ 20C
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BROWN LIQUID, MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:PHOSPHORUS OXIDES, SULFUR OXIDES,
CARBON MONOXIDE.
Disposal
Waste Disposal Methods:PROD SUITABLE FOR BURNING IN ENCLSD, CONTROLLED
BURNER FOR FUEL VALUE/DISP BY SUPERVISED INCIN. BURNING MAY BE LTD
PURSUANT TO RCRA. IN ADDN, PROD SUITABLE FOR PROCESSING BY APPRVD
RECYCLING FACILITY/ CAN BE DISP OF @ ANY GOVT APPRVD WASTE (ING 17)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.